DisplayGrph_logo

This page require Adobe Flash 9.0 (or higher) plug in.

Furnace / Heaters

gr_el140H

EL-140H

Amount of Space Unit Heats

up to 3500 Square feet

Commonly Used Fuels

Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil, and diesel fuel

Fuel Meter Pump

Precision metering over a wide range of fuels

UL Certification

UL listed system

Fuel Flow Rate

1.0 gallons/3.78 liters per hour

BTU Input

142,000 BTU/41.6 kW per hour

Warm Air Temp. Rise

100-120 F/37.8-48.9 C

Air Flow

1000 cfm/28 cu. m/min

Warm Air Outlet Dimensions

12"W x 12"H /31cm W x 31cm H

Ductible dual outlets

Air outlet can be on both sides

Primary Heat Exchanger

18 gauge high temperature and corrosion resistant stainless steel, UL-rated at 1500 F/816 C

System Dimensions

Cabinet -

18"H x 18"W x 92"L / 46cm H x 46cm W x 234cm L

With Tank -

37.5"H x 32"W x 60"L (69"L w/pump)

95cm H x 82cm W x 153cm L (176cm L w/pump)

Hour Meter

Analog (Clocks only actual burn time, not blower)

Exhaust Flue Diameter

8" / 20.32cm diameter

Fuel Tank

Single wall 250 gal./946.35 liter workbench. Double wall workbench available

Electrical Req.

115 VAC 60Hz, 25 amps dedicated circuit

Shipping Weight

System with tank - 730lbs. / 332kg

System without tank - 375lbs. / 171kg

Standard Features

Integrated Air Compressor Barometric Damper, Draft Gauge, Squirrel Cage Blower

Optional Features

Various Size Fuel Tanks, Dual Warm Air Outlet Louvers

 

gr_el200H

EL-200H

Amount of Space Unit Heats

up to 5000 Square feet

Commonly Used Fuels

Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil, and diesel fuel

Fuel Meter Pump

Precision metering over a wide range of fuels

UL Certification

UL listed system

Fuel Flow Rate

1.4 gallons/5.3 liters per hour

BTU Input

200,000 BTU/58.3 kW per hour

Warm Air Temp. Rise

100-120 F/37.8-48.9 C

Air Flow

1500 cfm/42 cu. m/min

Warm Air Outlet Dimensions

15"W x 15"H /38cm W x 38cm H

Ductible dual outlets

Air outlet can be on both sides

Primary Heat Exchanger

18 gauge high temperature and corrosion resistant stainless steel, UL-rated at 2000 F/1093 C

System Dimensions

Cabinet -

18"H x 18"W x 105"L / 46cm H x 46cm W x 267cm L

With Tank -

37.5"H x 32"W x 60"L (69"L w/pump)

95cm H x 82cm W x 153cm L (176cm L w/pump)

Hour Meter

Analog (Clocks only actual burn time, not blower)

Exhaust Flue Diameter

8" / 20.32cm diameter

Fuel Tank

Single wall 250 gal./946.35 liter workbench. Double wall workbench available

Electrical Req.

115 VAC 60Hz, 25 amps dedicated circuit

Shipping Weight

System with tank - 750lbs. / 341kg

System without tank - 395lbs. / 180kg

Standard Features

Integrated Air Compressor Barometric Damper, Draft Gauge, Squirrel Cage Blower

Optional Features

Various Size Fuel Tanks, Dual Warm Air Outlet Louvers

 

gr_el340H

EL-340H

Amount of Space Unit Heats

up to 8500 Square feet

Commonly Used Fuels

Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil, and diesel fuel

Fuel Meter Pump

Precision metering over a wide range of fuels

UL Certification

UL listed system

Fuel Flow Rate

2.25 gallons/8.5 liters per hour

BTU Input

340,000 BTU/99.6 kW per hour

Warm Air Temp. Rise

100-120 F/37.8-48.9 C

Air Flow

2800 cfm/79 cu. m/min

Warm Air Outlet Dimensions

19"W x 25"H /48cm W x 64cm H

Ductible dual outlets

Air outlet can be on both sides

Primary Heat Exchanger

18 gauge high temperature and corrosion resistant stainless steel, UL-rated at 2000 F/1093 C

System Dimensions

Cabinet -

28"H x 22"W x 99"L / 71cm H x 56cm W x 252cm L

With Tank -

37.5"H x 32"W x 60"L (69"L w/pump)

95cm H x 82cm W x 153cm L (176cm L w/pump)

Hour Meter

Analog (Clocks only actual burn time, not blower)

Exhaust Flue Diameter

8" / 20.32cm diameter

Fuel Tank

Single wall 250 gal./946.35 liter workbench. Double wall workbench available

Electrical Req.

115 VAC 60Hz, 25 amps dedicated circuit

Shipping Weight

System with tank - 895lbs. / 406kg

System without tank - 545lbs. / 248kg

Standard Features

Integrated Air Compressor Barometric Damper, Draft Gauge, Squirrel Cage Blower

Optional Features

Various Size Fuel Tanks, Dual Warm Air Outlet Louvers


 
Search
Total Tool Video

graphic_video
Contact Us

Total Tool
10 Kids Lane

Castleton, NY 12033

Phone: 518-766-7676
Fax: 518-766-4051
Toll Free: 1-800-677-8685

info@total-tool.com